BodyMed®, 3 Section Hi-Lo Treatment Table Blue
- BodyMed®
- Accessories & Device
- BODYMED002
- 10.00 lbs
$3,854.80
We Also Suggest
View All
The BodyMed 3 Section Hi-Lo Treatment Table offers practitioners dependable, highquality support for various treatments and therapies. Featuring a sleek, stylish design, this
versatile electric hi-lo treatment table includes three sections constructed to withstand heavy
manipulation supported by an impact-resistance steel frame. Included with the table are gas
struts that easily adjust the moveable top sections of the table. Additional features include
foot levers, hand levers, a contoured face opening, and a cushioned face plug. This treatment
table has a maximum weight capacity of 496 lb. (225 kg); is ADA compliant; is cushioned
with a 2-in., high-density foam covered in durable vinyl upholstery; and features seamless,
rounded corners.
Features
• Sleek, stylish design
• ADA compliant
• Heavy-duty steel frame
• Adjustable head section
• Adjustable leg section
• Contoured face opening
• Cushioned face plug
• Hand and foot levers
• Four (4) retractable casters with
activator levers
• Four (4) leveling feet
• 2-in. high-density foam top
• Seamless, rounded corners
• Vinyl upholstery
• Color: Blue or black
Cleaning Instructions
1. Unplug the table from the wall outlet. Failure to do so may result in serious bodily
injury, including electrocution and death.
2. Move the table to a cleaning area if necessary.
3. Dilute a neutral detergent (pH 7 only) with warm water.
4. Clean the hand and foot controls with alcohol wipes.
5. Dry the table with a towel before use.
6. Use a diluted solution of hypochlorite with cold water (mix at 10,000 ppm)
to decontaminate the table.
Maintenance & Servicing
Regular maintenance and servicing are recommended by a professional inspector to ensure
the table complies with the required standards for the continual use of the table. All electrical
servicing and maintenance must be performed by a qualified professional. Blue or brown wires
must not be connected to the ground wire.
1. Unplug the table from the wall outlet. Failure to do so may result in serious bodily injury,
including electrocution and death.
2. Visually inspect before each use for signs of damage and ensure all fasteners (nuts, bolts,
screws, etc.) are present and secured properly. Do not overtighten fasteners as this may
cause binding between components and/or shaking.
3. Inspection and servicing should be performed regularly every 6 months of normal use.
Increase the frequency of inspection and servicing in proportion to the frequency of use.
4. Check each section of the table top to ensure all sections are securely fastened to the
supporting frame. Any loose bolts or screws should be tightened before use.
5. Check the gas struts underneath the table top to ensure each section moves smoothly. The
table top should be locked once the release lever is released.
6. Check all cables connected for cuts or signs of wear/deterioration.
7. Check the connectors to the control box from the actuator to ensure they are secured in
their correct socket; check the main power cord is plugged into the main wall socket.
Product Specifications
• Maximum Weight Capacity: 496 lb. (225 kg)
• Minimum Height: 18 in. (460 mm)
• Maximum Height: 36 in. (910 mm)
• Head Section Length: 16 in. (410 mm)
• Mid Section Length: 25 in. (640 mm)
• Leg Section Length: 33 in. (850 mm)
• Total Length: 77 in. (1,955 mm)
• Table Width: 27 in. (700 mm)
• Head Tilt Angles: -30° to +80°
• Leg Tilt Angles: 0° to +80°